Joyclima fresh air heat pump model and parameter
Hanging type Fresh Air Heat Pump series parameter sheet |
Model | Model number | | ZJXRA-100 | ZJXRA-150 | ZJXRA-200 | ZJXRA-300 | ZJXRA-400 |
Installation mode | | Hanging type | Hanging type | Hanging type | Hanging type | Hanging type |
Rated cooling capacity | W | 650 | 750 | 830 | 2000 | 2300 |
Rated heating capacity | W | 750 | 800 | 950 | 2500 | 2800 |
Rated cooling power | W | 240 | 260 | 290 | 550 | 630 |
Rated cooling current | A | 1.1 | 1.23 | 1.37 | 2.6 | 3 |
Rated heating power | W | 240 | 260 | 290 | 610 | 685 |
Rated heating current | A | 1.1 | 1.23 | 1.37 | 2.9 | 3.3 |
Max operation power | W | 380 | 400 | 430 | 750 | 800 |
Max operation current | A | 1.8 | 1.9 | 2.04 | 3.6 | 3.8 |
Compressor | / | Constant speed compressor | Constant speed compressor | Constant speed compressor | Constant speed compressor | Constant speed compressor |
Power | Power supply | V/Ph/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 |
Fresh air/Exhaust air flow | m3/h | 30~100 | 70~150 | 100~200 | 150~300 | 220~400 |
External static pressure | Pa | 50 | 80 | 80 | 130 | 130 |
Noise | dB(A) | 31 | 31 | 31 | 31 | 32 |
Air outlet dimension | mm | 100 | 150 | 150 | 184 | 184 |
Condensate drainage size | inch(BSP) | 1/2" | 1/2" | 1/2" | 1/2" | 1/2" |
Machine size(L/W/H) | mm | 840/685/250 | 840/685/250 | 840/685/250 | 1170/760/400 | 1170/760/400 |
Packing size(L/W/H) | mm | 891/731/358 | 891/731/358 | 891/731/358 | 1211/811/498 | 1211/811/498 |
Net weight/Gross weight | Kg | 43/50 | 43/50 | 43/50 | 120/135 | 95/113 |
Refrigerant | / | R134a | R134a | R134a | R410A | R410A |
1.Features:
Ventilating(reducing CO2),ultra low noise,heat exchange(energy recovery ),heat pump system(cooling and heating),multistage filtration,remove formaldehyde,dehumidify,save energy(environment protection),intelligent.(visualize quality air).
2.Attractive:
Air quality analysis of indoor :
CO2 less than 1000ppm: fresh air, breathe smoothly;
CO2 1000ppm~2000ppm: the air is getting thick.
CO2 2000ppm~5000ppm: make you want to sleep easily or get the headache;
CO2 Larger than 5000ppm: lack of oxygen seriously or cause coma.
If you install Joyclima fresh air heat pump, indoor CO2 is 500ppm-600ppm, you could get fresh air and breathe smoothly.
3.Advantage:
1. Heat exchanger and heat pump system make up the double-stage energy recovery system.
2. Balancing ventilation, efficient and rapid handing of indoor air, increasing air quality.
3. DC mute fan.
4. Specially designed high efficiency and low resistance PM2.5 filter screen. Indoor PM2.5 removing could be nearly 100%.
5. Home environment real-time monitoring.
6. Joyclima fresh air heat pump got the invention patent.
7. Adopt the plate heat exchanger, control of temperature difference and reduce the pollution source.
8. Joyclima fresh air heat pump with high heat recovery exchange efficiency.