Partial parameters of Fresh air heat pump X100
Model | Cooling capacity (W) | Heating capacity (W) | Power (V/Ph/Hz) | Fresh air (m3/h) | External static pressure (Pa) | Net/gross weight (Kg) | Machine dimension (mm) |
X-100 | 650 | 750 | 220-240/1/50 | 30~100 | 12 | 43/48 | 860/600/263 |
Test conditions:
Heating conditions:Ambicnt dry bulb / wet bulb tcmpcraturc7*C/6 < C; Room dry bulb : wet bulb tcmpcraturc20XT/15*C
Cooling conditions:Ambient dry bulb / wet bulb temperaiure35*C/24X^ ;Room dry bulb / wet bulb temperature27*C/19"C
Fresh Air Heal Pump only handles fresh air.
1. The heating/cooling capacity and heat recovery volume is calculated according to the following conditions:( Remarks: )
Heating: ambient DB=7°C, ambient WB=6°C, indoor DB=20°C Cooling: ambient DB=35°C, ambient WB=24°C, indoor DB=26°C
2. The airflow is controlled according to the ambient temperature:
Ambient temperature<-15°C, airflow=30 m3/h.
-15°C<=ambient temperature<0°C, airflow=70m3/h.
Ambient temperature>=0°C, airflow=100m3/h.
Configuration1. Crossflow heat exchanger: Made of Aluminum, cross flow passages, sensible heat exchanger.
2. Fresh air filters: Triple filtration to ensure air cleanness, G4+F7+Activated Carbon. Aluminum frame, solid, stable, ametabolic and anti corrosive.
3. Return air filter: Nonwoven material, G4 class, filtering return air. -Aluminum frame, solid, stable, ametabolic and anti corrosive.
4. Bypass system: By adjusting the opening angle, different fresh air volume can go through theheat exchanger and by-pass synchronously. When it’s opened completely, the air goes without passing the heat exchanger.
5. Compressors: Made by Panasonic, rated cooling capacity is 650W. -R134a refrigeration, environment friendly.
6. Evaporator: Plate fin heat exchanger, with coated hydrophilic fins.
7. Connection box: Circuit board, core of intelligent control system -Power switch, power supply to the compressor, fans and by-pass Wiring terminal, easy access for field connection.
8. Drain tray: Made of coated galvanized steel, collecting the drain water from heat exchanger, evaporator and condenser.
9. Drain pump: -Integrated with ball cock to test the water level, the water is drain out automatically if the water is full.
FAQ
Q1.Can you have a sample route scheme for the duct?
A 1: Of, course, we would like to help you to some degree.
Q2.Is that machine quite in noise, suit for bedroom requirement?
A 1: Of, course, the lowest noise can fell to 31dB(A).
Q3.How frequent do I need to change the filter?
A 3: Normally, the filter should be replaced every six months periodly, actually it also depends on specific environment, hence we develop our own controller which can alert the user to change filter through the LCD screen alarm function.
FAQ
Q1:what’s your machine’s advantage?
A1: Double-stage heat recovery, much more efficient in minimise the effection of temperature during ventilation.
Q2:can you accept customized needs?
A2: we can do OEM sevice for customers. The specifc needs can be negotiated
Q3:Are your machines energy-saving?
A2: yes, our whole series adopts EC fan motor, less electricity cost, and safer.
Q4: Do your machines have controller board to monitor its operation?
A4: yes, our machines are equipped with our own developing system integrated into its controller board, it’s convenient for customers to ask to find problem accurately and timely.
Q5: how do you guarantee your service timely?
A5: both of our engineers and salesmen work at factory office, it can reflect customers’ feedback as soon as possible after shortening the distance between sale department and technical department.
Q6: Can your own system be interfaced with other control center by establish communication protocols?